What should 407C pressures be?

What should 407C pressures be?

R-407C Pressure Chart

Temp (F) Temp (C) Liquid Pressure (PSIG)
96.8 36 215.04
100.4 38 226.77
104 40 238.92
107.6 42 251.53

Can you put R22 in a 407C system?

If your system is running on R22 most likely is using mineral oil to lubricate the compressor. If you mix R407C with R22 inside your system the molecule of the HFC (R407C) gas will not link with the oil and in just few months of operation you will have a “sludge” like lubricant formation inside the circuit.

How much does 407C refrigerant cost?

R407C Refrigerant Price per Pound R407C is a non-ozone depleting refrigerant that contributes somewhat to global warming, even though it is still a preferable option to R22 coolant. On average, Refrigerant 407C price ranges between $4 and $7 per pound.

Can you mix 407C with 410A?

Freon™ 407C refrigerant performs similarly to HCFC-22 under evaporator temperatures ranging from –7 to 10 °C (20 to 50 °F). Due to the significantly higher pressures that Freon™ 410A exhibits compared to HCFC-22, a typical compressor designed for HCFC-22 cannot be used with Freon™ 410A.

What should the high and low side pressures BE for 407C?

Re: R407c Pressures If this is so always evaporating above zero, 4 or 5 deg celcius, R407c will have a low pressure (suction ) of about 50 psi. and a high pressure ( discharge ) of about 280 psi, which is about 55 deg celcius, cooling cycle.

What is good superheat for 407C?

For R22 systems the superheat should be between 3°C and 5°C, for R407C systems the TX valve should be adjusted to achieve 6°C to 8°C super heat. Systems for R407C must have a TX valve fitted which allows for this adjustment to be done.

What oil does 407C use?

polyolester oil
R407C units will contain polyolester oil (POE). Check the compressor label to confirm the type of oil in the system. For safe system operation it is essential to remove the mineral oil from the existing system, as R407C is not compatible with mineral oil.

Is it illegal to mix refrigerants?

You’re wondering if you can mix different refrigerants for your air conditioning system. The short-long-only answer is no, never. There are many reasons why it’s impractical, illegal, and not economical for a homeowner to mix refrigerant types.

Are 134a and 410A compatible?

The United States explicitly prohibit the use of R410A and R134a refrigerant.

How much does a R-407C refrigerant cost?

R407C, R-407C, R-407, R22 Alternate, Refrigerant. $95.00.

Which is a better refrigerant R-404A or R-407A?

This non-ozone depleting, hydrofluorocarbon (HFC) refrigerant is a replacement for R-22 and provides a lower global warming potential (GWP) alternative to R-404A and R-507. The flexibility of Freon™ 407A enables a range of options, including:

Can a freon 407C be topped off multiple times?

An ability to be topped off after a leak, multiple times, with minimal impact on system performance Safety; Freon™ 407C has an ASHRAE A1 safety classification Regulations on the long-term use of refrigerants vary by region and application, and may change over time.

When to use refrigerant gas R407c in an air conditioner?

Refrigerant gas r407c is an HFC retrofit refrigerant for 22. It is used in air conditioner and Non-centrifugal refrigeration system. Storage should be away from fire, heat and avoid direct sunlight, it usually put in a cool, dry and ventilated place .In case the cylinder,valves and other accessories are damaged ,it should be handled with care .